Test operation of round separator
Usually some customers don’t know how to operate after receiving the machine. EVERSUN machinery will explain the test procedure for you.
- Turn off the power switch, and then run it for 20-30 minutes without any operation. Normally, the motor should run counterclockwise. If the direction is wrong, adjust the three-phase power supply.
- It should be confirmed that the vibration motor is running within the rated current range. At the beginning of operation, especially in low temperature occasions, the current will be slightly higher, but within 20-30 minutes, it should be reduced to the rated current value.
- There should be no abnormal sound on the round separator. If there is an abnormal sound, it should be quickly turned off for inspection. The abnormal sound is usually caused by loosening of the fastening components. Especially during transportation and assembly after disassembly, please pay attention to the fastening of each part. The round separator has an instantaneous resonance zone (1-3 seconds) when it starts and stops. At this time, the amplitude and noise will increase significantly, which is normal.
- After idling, a small amount of material can enter the screen through the feed port, and then slowly increase to the required tolerable feed amount. At this time, the weight should be adjusted according to the net surface discharge to make the efficiency of the screening machine reach the best state.
Our main product are Sieving machine,Vibro sifter machine,Ultrasonic sieving machine,Vacuum conveyor,Dumping station, Tumbler screening machine, Industrial sieving machine, Liquid filter, Rectangular gyratory sifter, Screw conveyor and etc.
Please feel free to contact us if you need any support.
Sales Dep: Sales@vibrosievingmachine.com, Cell/WhatsApp:+86 13162301696